The direct answer

A nail-salon workstation brief should begin with the actual treatment menu and products, then define how vapours and dust are captured near the source, how the room is supplied and exhausted, where air is discharged, how filters and ducts are maintained, and how technicians and clients sit comfortably. Do this before ceilings, counters and mechanical services are designed. A polished manicure table without a verified air path can create false confidence. The final ventilation strategy must be developed by competent specialists against current Dubai requirements and the selected equipment data.

Map services and products first

List every manicure and pedicure service, the products used, expected station time and maximum number of simultaneous treatments. Obtain current safety data sheets from product suppliers and note whether tasks create vapours, liquid spills or filing dust. A salon that offers basic polish only has a different exposure profile from one using acrylic or other enhancement systems. The brief should also record storage quantities, decanting practices, waste route and cleaning method. This operational information is the input to ventilation design, not an afterthought once the furniture has been ordered.

Separate room ventilation from local capture

General ventilation dilutes contaminants in the room; local exhaust aims to capture them close to the task before they spread. CDC NIOSH identifies chemical and physical hazards for nail technicians and notes that local exhaust can include downdraft ventilated tables. OSHA likewise emphasises room ventilation and functioning workstation systems. These sources are occupational guidance rather than a substitute for Dubai design approval, but they support a clear principle: define both the whole-room air strategy and the source-capture strategy, then test how they work together.

Use a six-part equipment comparison

Compare capture position, verified airflow, filtration or discharge route, noise, maintenance and ergonomics. Capture should be close to the work without obstructing hands. Product data should state how airflow is achieved and what maintenance is required. Noise matters because a system that staff switch off is ineffective. Filters need accessible replacement and a safe waste procedure. Ducted systems need coordinated routes and discharge review. The table must still provide knee clearance, task-lighting space and an adjustable working relationship between technician and client.

  • Capture location and task coverage
  • Airflow data and commissioning method
  • Filter or external discharge strategy
  • Noise at normal operation
  • Cleaning and maintenance access
  • Technician posture and client comfort

Coordinate the workstation with the building

Each station can require power, task lighting, extract connection and accessible components. Pedicure stations may add water, drainage and specialist equipment interfaces. Show connections in a room data sheet and confirm what is supplied with the furniture versus the building fit-out. Avoid flexible hoses laid across circulation or inaccessible filters trapped behind fixed panels. The mechanical designer should check interaction with supply-air diffusers, return air and pressure relationships so that room airflow does not push contaminants through the client or technician breathing zone.

Planning example

Planning example: a salon plans six manicure positions but expects only four to operate together during normal trading. The design still reviews the approved maximum simultaneous use. Two table models are compared: one recirculates through replaceable filters, while the other connects to a designed extract route. The team evaluates product data, contaminant suitability, noise, maintenance access, discharge constraints and technician posture before selecting a system. This is a planning scenario, not a completed salon or a guaranteed approval route.

Chemical storage and daily behaviour matter

Ventilation cannot compensate for poor handling. Keep containers closed when not in use, use suitable dispensers, separate incompatible products and provide storage that follows current product information and Dubai requirements. Plan a cleanable work surface, small-waste route and spill response without turning the client area into a chemical store. Dubai Municipality publishes salon compliance and ideal-salon guidance; the current applicable documents and licence conditions should be confirmed for the business. Train staff on the installed system, because airflow depends on correct use as well as design.

Workstation briefing checklist

Use one schedule for the operator, designer, furniture supplier and mechanical team.

  • List treatments, products and maximum simultaneous stations
  • Collect current safety data sheets and equipment manuals
  • Define general ventilation and local-capture responsibilities
  • Show extract, power, lighting and any water or drainage points
  • Check technician posture, client comfort and circulation
  • Provide accessible filters, ducts and cleaning components
  • State noise, airflow and commissioning evidence required
  • Include operating, maintenance and staff-handover records

Commissioning and handover

Before opening, verify that the installed tables, fan settings, filters and duct routes match the approved design. Record airflow or other agreed performance checks at each station, test controls, and confirm that staff know when the system must run. Add filter and cleaning tasks to the maintenance calendar with named responsibility. Re-test after furniture changes, duct alterations or a significant treatment-menu change. A handover file should include equipment references, manuals, safety data sheets, test results, replacement filters and the route for reporting faults.

Important limitations

This article does not calculate ventilation rates, select filters or determine exposure limits. Those depend on the products, tasks, occupancy, equipment and current regulatory requirements. US occupational sources are useful evidence about hazards and controls but are not Dubai approval documents. The Dubai Municipality guidance and project-specific authority route must be checked by the appointed professionals. Do not improvise extract discharge, modify listed equipment or rely on masks as a substitute for a properly designed engineering-control strategy.

A sensible next step

Before the ceiling and counter concepts are frozen, hold a workshop with the salon operator, mechanical designer, fit-out designer and proposed workstation supplier. Review one treatment from product storage through service and waste. Mark the capture point, airflow route, connections, filter access, cleaning zone and technician posture on a coordinated section. Then use that same section and room data sheet to price competing systems and define commissioning evidence.

Sources & further reading

Make this useful for your project.

A review of your property and priorities can turn general guidance into a defined brief.

Explore Salon fit outDiscuss your project
Return to the journal